Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
China Pharmacy ; (12): 4146-4147,4148, 2015.
Article in Chinese | WPRIM | ID: wpr-605053

ABSTRACT

OBJECTIVE:To provide reference for continuous improvement of drug counseling and pharmaceutical care. METH-ODS:220 cases of drug counseling answered by inpatient general pharmacist were collected from our hospital during 2012-2013, and the contents of drug counseling were classified and analyzed. RESULTS:Among consultants,73.18% of them were physi-cians;the type of drug involved mainly were antibiotics,accounting for 42.73%;main contents of drug counseling included drug selection,usage and dosage,accounting for 47.27%. CONCLUSIONS:Pharmacists provide drug counseling for physicians and nurses,answer various questions about usage,and guide rational drug use so as to enhance the communication between pharma-cists and physicians,nurses,and promote rational drug use in the clinic.

2.
China Pharmacy ; (12)2007.
Article in Chinese | WPRIM | ID: wpr-533104

ABSTRACT

OBJECTIVE:To establish a rapid and sensitive HPLC method for simultaneous determination of plasma concentrations of 6 antidepressants.METHODS:With diprozin as internal standard,the alkalized samples were extracted by liquid-liquid extraction and separated on a Phenomenex-C18 column using acetonitrile-0.05 mol?L-1 sodium dihydrogen phosphate(pH was adjusted to 2.5 by phosphoric acid) as mobile phase at a flow rate of 1.2 mL?min-1 by a gradient elution.The column temperature was set at 40℃.Venlafaxine was detected by fluorescence detection at an Ex wavelength of 276 nm and Em wavelength of 598 nm;doxepin,paroxetine,sertraline,fluoxetine and amitriptyline were detected at an UV detection wavelength of 200 nm.RESULTS:The linear ranges of venlafaxine,doxepin,paroxetine,sertraline,fluoxetine and amitriptyline were 5~1 000 ?g?L-1,40 ~200 ?g?L-1,20~800 ?g?L-1,40~1 000 ?g?L-1 and 10~400 ?g?L-1,respectively,with correlation coefficients ≥0.990 for all.Both the intra-day RSD and inter-day RSD were less than 15%;the extraction recovery rates were greater than 60% and methodological recovery were greater than 90% for all the samples.CONCLUSION:The method is simple,economical,rapid,accurate and sensitive,and it is applicable for the clinical monitoring of plasma drug concentrations as well as the analysis and pharmacokinetic study of toxic drugs.

SELECTION OF CITATIONS
SEARCH DETAIL